Книга: Microsoft Windows Embedded CE 6.0 Exam Preparation Kit

Running Clientside.exe Manually

Running Clientside.exe Manually

If you have included the Windows Embedded CE Test Kit catalog item in your runtime image, downloaded the CETK components with the workstation server application, or exported the components from your development workstation to the target device by using the File Viewer remote tool, you can start Clientside.exe on the target device and establish a connection to a workstation server manually. If your target device does not provide the Run dialog box for this purpose, open the Target menu in the Platform Builder IDE, select Run Programs, select Clientside.exe, and then select Run.

Clientside.exe supports the following command-line parameters that you can specify to connect to a specific workstation server application, detect installed drivers, and run tests automatically:

Clientside.exe [/i=<Server IP Address> | /n=<Server Name>] [/p=<Server Port Number>] [/a] [/s] [/d] [/x]

It is important to note that you can define these parameters also in a Wcetk.txt file or in the HKEY_LOCAL_MACHINE/Software/Microsoft/CETT registry key on the target device so that you can start Clientside.exe without command-line parameters.

In this case, Clientside.exe searches for Wcetk.txt in the root directory, then in the Windows directory on the target device, and then in the release directory on the development workstation. If Wcetk.txt does not exist in any of these locations, it checks the CETT registry key. Table 4-5 summarizes the Clientside.exe parameters.

Table 4-5 Clientside.exe start parameters

Command Line Wcetk.txt CETT Registry Key Description
/n SERVERNAME ServerName (REG_SZ) Specifies the host server name. Cannot be used together with /i and requires Domain Name System (DNS) for name resolution.
/i SERVERIP ServerIP (REG_SZ) Specifies the host IP address. Cannot be used together with /n.
/p PORTNUMBER PortNumber (REG_DWORD) Specifies the server port number that can be configured from the workstation server interface.
/a AUTORUN Autorun (REG_SZ) When set to one (1), the device automatically starts the test after the connection is established.
/s DEFAULTSUITE DefaultSuite (REG_SZ) Specifies the name of the default test suite to run.
/x AUTOEXIT Autoexit (REG_SZ) When set to one (1), the application automatically exits when the tests are completed.
/d DRIVERDETECT DriverDetect (REG_SZ) When set to zero (0), the detection of devices drivers is disabled.